Replacing the Fusing Unit
19
1
Replacing the Fusing Unit
R
CAUTION:
If "Replace Fusing Unit (Type C)" ap-
pears on the panel display, replace
the Fusing Unit.
A
AA
A
Turn off the power switch and
unplug the power cable.
Important
Be sure to wait about an hour to
prevent a burn.
B
BB
B
If the 2 Tray Finisher is installed,
detach it from the printer.
Reference
See p.1 Detaching the SR770 (2
Tray Finisher)
C
CC
C
If the Duplex Unit is installed,
open the Duplex Reversal Unit.
Reference
See p.2 Opening and Closing
the Duplex Reversal Unit
D
DD
D
If the External Tray is attached to
the printer, raise it in the direc-
tion of the arrow (A
AA
A), and remove
it (B
BB
B).
E
EE
E
Pull out the left cover of the print-
er.
F
FF
F
Open the upper left cover.
Important
Do not touch any areas other
than the handle.
The Fusing Unit becomes very
hot. When installing the new
Fusing Unit, turn off the printer
and wait about an hour. After
that, install the new Fusing Unit.
Not waiting for the unit to cool
down can result in a burn.
Replace Fusing
Unit (Type C)
ZDJP038J
ZDJH047J
ZDJH048J
JupP1k_GB_Mainte_F_FM.book Page 19 Thursday, August 22, 2002 4:23 PM