Page view 5
4-M4 Depth 4
15.5
±0.05
14.5
±0.05
16.8
±0.05
25
±0.05
35
30.2
35
(55.3)
50.8
4-R3
φ36
0
−0.05
1/4”20UNC(Screw for Tripod)
10.5
U1(C Mount Screw)
φ31
A
B
C
Pin No. Signal name IN/OUT Signals Initial output signal
1 GND IN GND
2 I/O-1 OUT +3.3V LVTTL Frame Trigger Wait
3 I/O-2 OUT +3.3V LVTTL Exposure Active
4
TRIGGER_In-
IN Isolated -
5
TRIGGER_In+
IN Isolated +
6 POWER IN IN +10.8 to +26.4 Vdc
B
C
A
GigE
Vision
2 Mega-
pixel
FV-G200B1
FV-G200B1 Product specifications
Imager 1/1.8" interline UXGA monochrome progressive CCD
Active picture elements UXGA class : 1624 (H) × 1236 (V)
Cell size 4.4 (H) × 4.4 (V) µm
Vertical frequency
(Frame rate)
15.31668 Hz
Horizontal frequency 19.1761 kHz
Pixel frequency 36.818175 MHz
Minimum scene illumination 0.16 lux at F1.2
Sync. System Internal
Video output Digital 8, 10 or 12 bit Raw data GigE Vision
Exposure time
Preset free-run mode: 10 µ seconds to 16,777,216 µ seconds
Preset trigger mode: 10 µ seconds to 16,777,216 µ seconds
Pulse width mode: 10 µ seconds to Unlimited
Gain 0 to 20.4 dB
Gamma 1.0
Power
Input voltage + 10.8 to + 26.4 Vdc
Consumption Less than 5.0 W
Dimensions 35 (W) × 35 (H) × 50.8 (D) mm (excluding the connector)
Lens mount C mount
Weight Approximately 120 g
Operational
environment
Temperature
(Min)
Environmental temperature -5 deg. C
Storage
Temperature
(Max)
Environmental temperature 35 deg. C or
camera housing temperature (Top plate): 65 deg. C
Note: Please use the unit under conditions that satisfy at least one of the above criteria. In
cases where the ambient temperature exceeds the above limit, when installing the unit
please take suitable heat dissipation measures so that the upper portion of the case stays
at a temperature of 65˚C or less. Inside this unit, between the case and the electronic
components we have taken thermal resistance measures of as small a size as possible. As
a result, by controlling the case temperature, it is possible to keep the camera’s internal
electronic components within the rated level.
DC iris lens connector M1951(EMUDEN-made) equivalent
Note: For details, see product specifications.
Input/output signal connector Hirose-made HR10A-7R-6PB equivalent
Power input and input/output signal input can be done.
Optional connector RICOH FP-CN6PB is supported.
RJ45 connector Note: Not PoE type. Power provided separately from
C
.
GigE Vision
2 Megapixel Camera
High-speed frame rate of 2M: 15 fps
High image quality with a CCD global shutter
Camera contains automatic control functions for gain and shutter
Various scan modes (full, AOI) as standard features
Various trigger modes (pulse width, edge preset trigger) as
standard features
Supports DC iris lens so also excellent for outdoor monitoring uses
Excellent for industrial uses as it handles a wide voltage range
(10.8 - 26.4 V)
Supports updating of camera firmware via Ethernet
In addition to camera tripod screw holes, M4 screw holes are located
on two sides (top and bottom)
Highly rigid case to increase mounting precision
Preprocessing functions and 2M GigE Vision for
a wide range of uses
Suitable for diverse inspection uses, including positioning before each process
in screen printing, circuit board mounted device part checks, automotive
component flaw detection, etc. Also excellent for outdoor monitoring uses.
Dimensions and rear connector specifications
[AOI* scan mode] raises inspection quality and speed with
efficient scanning
[Supported cameras]
FV-G200B1
,
FV-G030B1
AOI scan mode handles high-speed inspection. The user can freely define the
start line and width of the image data. By scanning images of only the necessary
portions, it is possible to transfer only the areas needed. This, in turn, makes it
possible to do speedy inspections by shortening the time required for reading
and transferring data.
*
Area of Interest
Image sensor image data
1. Eliminate hatched areas 2. Eliminate additional unnecessary areas
Transfer time reduced by sending only areas necessary for inspection
(Unit: mm)
06
Page view 5
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments