Ricoh AP4510 Service Manual Page 200

  • Download
  • Add to my manuals
  • Print
  • Page
    / 278
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 199
SELF-DIAGNOSTIC MODE
G065 5-42 SM
5.5.2 DETAILED SELF-DIAGNOSTIC MODE
In addition to the self-diagnostic test initiated every time the main machine is
powered on, you can set the machine in a more detailed diagnostic mode manually
in order to test other components or conditions that are not tested during self-
diagnosis after power on.
The following device is required in order to put the printer in the detailed self-
diagnosis mode.
No. Name
G0219350 Parallel Loopback Connector
Follow this procedure to execute detailed self-diagnosis.
1. Switch off the printer.
2. Press and hold down the !(On line) and #(Enter) buttons together, then switch
on the printer.
3. Release the buttons when you see:
DIAGNOSE
0100
4. The number will change automatically as the self-diagnostic test runs. After
about 30 seconds, the initial display returns and a self-diagnostic report prints.
A report like the one below is printed every time a detailed self-diagnostic test
is executed, whether errors were detected or not.
MODEL NAME XXXX
Serial No Firmware P/# :
ACP82XXXX
[1/1]
Firmware Version: 0.38
Fri Sep 7 05:45:18 2001
[System Construction]
Kernel Version : NetBSD 1.3.3 (HAKONE_RAM) #11: Sep 4 11:18:48 JST 2001
CPU System BusClock : 124.0 MHz CPU Pipeline Clock : 248.0 MHz
Board Type : 12 ASIC Version : 1128608306
RTC Existence
: existence
RAM Capacity : 67:108864 MB
HDD Existence
: existence
HDD Model :
[TotalCounter ]
0001000
[Error List ]
SCCODE (ERRORCODE ) SC CODE (ERROR CODE) SC CODE (ERROR CODE) SC CODE (ERROR CODE)
SC835 (1120)
Self-Diagnosis Report
G065S901.WMF
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Page view 199