TRANSFER UNIT
SM 3-27 G065
Replacement
and
Adjustment
3.12 TRANSFER UNIT
3.12.1 TRANSFER BELT UNIT
NOTE: To avoid exposing the PCU drum to strong light, cover it with paper if the
right cover will be open for a long period.
1. Lower the by-pass tray, open the duplex unit, and open the right cover.
2. Transfer unit [A] (1 hook)
3. Transfer belt [B] (springs x 2, 1 hook)
NOTE: Avoid touching the transfer belt surface.
G065R501.WMF
G065R522.WMF
[A]
[B]