PCDU
G065 3-16 SM
3.10.2 DRUM
1. PCDU (☛ 3.10.1)
CAUTION: Never touch the drum surface with bare hands.
2. Remove the toner cap [A] and use it to cover the toner port [B].
3. Turn the PCU upside down and remove the lower cover [C] (! x 2, pawls x 3)
4. Press at
➀
to release the charge roller [D], release the charge roller
➁
, press
the drum [E] to the front, and then remove the drum
➂
.
5. SP adjustments.
Charge Roller Bias Adjustment
2001-01
Set to the standard value
to ensure carrier is not
attracted to the drum.
ID Sensor Initial Setting 3001-02 Initializes the ID sensor.
Image Transfer Current – Image Face 2301 01
Image Transfer Current – Image Back 2301 02
Image Transfer Current – Lead Edge Face 2301 03
Image Transfer Current – Image Face By-pass 2301 04
Set to the default
settings.
G065R907.WMF
G065R908.WMF
G065R304.WMF
[A]
[B]
[C]
[D]
[E]