Ricoh SP 200 Specifications Page 84

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 83
+5VE is the 5 volt supply for energy saver mode. It saves energy by
supplying +5V power only for the components needed in energy saver mode.
Note that turning the main switch off is the same as entering auto shut off
mode.
Returning to standby mode
- From energy saver level 1 or 2 -
If one of the following is done, the machine returns to standby mode:
Pressing the Clear Mode/Energy Saver key
Placing an original in the ADF
Lifting up the ADF
The recovery time from energy saver level 1 is about 3 s.
The recovery time from energy saver level 2 is about 10 s (115 V machines)
or about 35 s (230 V machines).
- From auto shut off mode -
The machine returns to the ready condition when the main switch is turned
on.
The recovery time is less than 30 s for 115V machines, and less than 35 s for
230V machines.
Power Consumption
Mode Main
Switch
Energy
Saver LED
Fusing
Lamp
System
+5V
Note
Energy Saver
Level 1
On On 165°C On
The machine returns to standby
mode if the DF is lifted or an
original is placed in the ADF.
Energy Saver
Level 2
On On
140°C
(115V)
Room T
(230V)
On
Auto Shut Off
Mode Off Off Off Off
The machine returns to standby
mode only if the main switch is
turned on.
1 August 1996 ENERGY SAVER MODES
2-65
Page view 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 237 238

Comments to this Manuals