Ricoh Printer L4130 User Manual Page 146

  • Download
  • Add to my manuals
  • Print
  • Page
    / 174
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 145
5-12
Message Cause Solution
The ink of the ink cartridge has
been nearly used up.
Press the key to check the rel-
evant Eco-cartridge. Be careful because
it may be INK NEAR END soon.
Ink could not be supplied to the
damper.
Perform “DAMPER ( P.5-6) ” of the
maintenance. Also check the remaining
amount of ink in the Eco-cartridge.
Even if you performed this, when the
message is displayed, contact your local
distributor to call for service.
The liquid level sensor abnormality
of the damper has been detected.
Turn off the power to the machine and
turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
Overflow from the damper has been
detected.
Perform “DAMPER ( P.5-6) ” of the
maintenance. Also check the remaining
amount of ink in the cartridge.
Even if you performed this, when the
message is displayed, contact your local
distributor to call for service.
Though a certain amount was con-
sumed, there is no change in the
damper sensor High.
Though a certain amount was con-
sumed, there is no change in the
damper sensor Low.
To prevent settling out in the white
ink pack, this is displayed periodi-
cally.
Following the procedures, shake the
white ink cartridge. ( P.1-14)
The machine temperature is high.
Adjust the ambient temperature of the
installation place.
The machine temperature is low.
Time to replace the white ink filter with
a new one has come.
Following the procedures, replace the
white ink filter. ( P.4-34)
After “error 710 HEATER TEMP
ERROR” has occurred, the power is
forcibly turned off, and when you
restart it, this is displayed.
If the ERROR 710 appears again, con-
tact your local distributor to call for ser-
vice.
<LOCAL>
INK NEAR END [ENT]
<LOCAL>
SUPPLY I NK : MMCCYYKK
<LOCAL>
DAMPER Sen s : MMCCYYKK
<LOCAL>
I n kOv e r f l ow : MMCCYYKK
<LOCAL>
DAMPER / H I GH : MMCCYYKK
<LOCAL>
DAMPER / LOW : MMCCYYKK
SHAKE WH I TE I NK
CARTR I DGES [ ENT ]
<LOCAL>
MachineTEMP/Hi ***
°
C
<LOCAL>
MachineTEMP/Lo ***
°
C
<LOCAL>
F I L TER REPLACE
HEATER TEMP ERROR
POWER OF F [ ENT ]