Printer Engine Service Mode
M001 5-28 SM
RCG Read Timeout
5816 010
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
Port 80 Enable -
5816 011
Enables/disables access via port 80 to the SOAP method.
[0 or 1 / 0 / – ]
0: Disabled
1: Enabled
@Remote Service 1
5816 012
Enables/disables @Remote service.
[0 or 1 / 1 / – ]
0: Disabled, 1: Enabled
RCG-C Registed
5816 021
This SP displays the embedded RCG installation end flag.
0: Installation not completed
1: Installation completed
RCG-C Regist Det
5816 022
This SP displays the external RCG installation status.
0: External RCG not registered
1: External RCG registered
2: Device registered
Connect Type (N/M)
5816 023
This SP displays and selects the embedded RCG connection method.
[0 or 1 / 0 / 1 /step]
0: Internet connection
1: Dial-up connection
5816 061
Cert Expire Tim(ing)
DFU
Proximity of the expiration of the certification.
Comments to this Manuals