Service Call Conditions
SM 4-13 M001
Trouble-
shooting
835
(1102)
The controller detects that the
loop-back connector is not properly
connected.
• Loose connection
• Defective loop-back connector
• Defective Centronics connector
• Defective controller
(110C) A DMA data abnormality is detected
even when the loopback connector is
properly set.
1. Turn the main switch off and on.
2. Check the connection between
the Centronics connector and
loop-back connector.
3. Reconnect the loop-back
connector.
4. Replace the controller.
(1120) The loop-back connector is not set
when starting the detailed
self-diagnostics.
838 D
Self-diagnostic Error: Clock
Generator
Replace the controller board
A verify error occurred when setting
data was read from the clock
generator via the I2C bus.
851 B
IEEE 1394 I/F error
Driver setting incorrect and
cannot be used by the 1394 I/F.
NIB (PHY), LINK module defective;
change the Interface Board
Controller board defective
Rev. 11/03/2009