Fusing
SM 3-17 M001
Replacement
Adjustment
3.7.2 HOT ROLLER AND FUSING LAMP
1. Fusing Unit ( Fusing Unit)
2. Left cover [A] ( x 1)
3. Plate [B] ( x 2)
4. Upper fusing unit assembly [C] ( x 4, springs x 2)
5. Right cover [D] ( x 1)
6. Lamp holders [E] ( x 1 each)
Remove both springs before taking apart the fusing unit assembly. The reason
for this is to relieve pressure on the unit.
When reinstalling the fusing unit assembly, install both springs last. The
reason for this is to reset the springs back to their default position.