Service Call Conditions
M001 4-12 SM
833/834
C
For more details about SC 833, SC834 error.
Execute SP5990 to print an SMC report so you can
read the error code. The error code is not displayed
on the operation panel. The additional error codes
(0F30, 0F31, etc. are listed in the SMC report).
833
(0F30)
(0F31)
Self-diagnostic error 8: Engine I/F
ASIC
• ASIC for system control could not
be detected. After the PCI
configuration, the device ID for the
ASIC could not be checked.
• ASCI (Mandolin) for system control is
defective
• Interface between North Bridge and
AGPI is defective
(0F41) • ASIC for system control could not
be detected. After the PCI
configuration, the device ID for the
ASIC could not be checked.
• Memory device defective
• Replace the controller board
(50B1) Could not initialize or read the bus
connection.
• Bus connection defective, loose
• SSCG defective
• Replace the controller board
(50B2) Value of the SSCG register is
incorrect.
• Bus connection loose, defective
• SSCG defective
• Replace the controller board
⇒
Rev. 11/03/2009