Ricoh SP 1200S Service Manual Page 246

  • Download
  • Add to my manuals
  • Print
  • Page
    / 420
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 245
Worker Switch Settings (WSW)
M085/M086 5-56 SM
5.3.3 WSW02
Selector No. Function Setting and Specifications
1
2
Tone signal transmission time length
No. 1 2
0 0 : 70 ms
0 1 : 80 ms
1 0 : 90 ms
1 1 : 100 ms
3
4
Min. pause in tone dialing
No. 3 4
0 0 : 70 ms
0 1 : 80 ms
1 0 : 90 ms
1 1 : 140 ms
5 to 8
Attenuator for pseudo ring backtone to
the line (selectable in the range of 0-15
dB, in 1 dB increments)
No 5 = 0: 0 dB, 1: 8 dB
No 6 = 0: 0 dB, 1: 4 dB
No 7 = 0: 0 dB, 1: 2 dB
No 8 = 0: 0 dB, 1: 1 dB
Selectors 1 through 4: Tone signal transmission time length and Min. pause in tone
dialing
These selectors set the tone signal transmission time length [A] and minimum pause [B] in
tone dialing.
(Example: If "1," "2," "3," "4," and "5" are dialed.)
Selectors 5 through 8: Attenuator for pseudo ring backtone to the line
These selectors are used to adjust the sound volume of a ring backtone in the F/T mode,
an on-hold sound, or a beep generated as a signal during remote control operation or at the
start of ICM recording.
The larger the value specified by these selectors, the greater the attenuation.