Troubleshooting of the Control Panel
SM 6-79 M085/M086
Trouble –
shooting
6.9 TROUBLESHOOTING OF THE CONTROL PANEL
6.9.1 NOTHING IS DISPLAYED ON THE LCD.
User Check
Verify if the power switch is turned off.
Possible cause and Remedy
1. Connection between main PCB and control panel PCB
Are the main PCB and control panel PCB connected properly?
No: Reconnect the connector properly.
2. Connection between main PCB and LVPS PCB unit
Are the main PCB and LVPS PCB unit connected properly?
No: Reconnect the connector properly.
3. LCD
Is the problem solved after replacing the LCD?
Yes: Replace the LCD.
4. Control panel PCB
Is the problem solved after replacing the control panel PCB?
Yes: Replace the control panel PCB.
5. LVPS PCB unit
Is the problem solved after replacing the LVPS PCB unit?
Yes: Replace the LVPS PCB unit.
6. Main PCB
Is the problem solved after replacing the main PCB ASSY?
Yes: Replace the main PCB ASSY.