Error Cause
SM 6-13 M085/M086
Trouble –
shooting
Error code 68/ 69/ 6A/ 6B/ 6C/ 6D/ 6E/ 6F
Error code 68
Print Unable 68
See Troubleshooting and routine maintenance chapter in User’s
Guide.
Fuser unit failure (The side thermistor detects higher temperature than the specified value.)
Error code 69
Print Unable 69
See Troubleshooting and routine maintenance chapter in User’s
Guide.
Fuser unit failure (The side thermistor detects lower temperature than the specified value.)
Error code 6A
Print Unable 6A
See Troubleshooting and routine maintenance chapter in User’s
Guide.
Fuser unit failure (The side thermistor does not detect 60°C within the specified time.)
Error code 6B
Print Unable 6B
See Troubleshooting and routine maintenance chapter in User’s
Guide.
Fuser unit failure (The center thermistor does not detect 100°C within the specified time.)
Error code 6C
Print Unable 6C
See Troubleshooting and routine maintenance chapter in User’s
Guide.
Comments to this Manuals