Worker Switch Settings (WSW)
M085/M086 5-70 SM
5.3.11 WSW10
Selector No. Function Setting and Specifications
1 DPS switching interfacing with CML 0: No 1: Yes
2
Time length from transmission of the
last dial digit to CML ON
0 : 100 ms 1: 50 ms
3
Time length from CML ON to CNG
transmission
0 : 2 sec. 1: 4 sec.
4
Time length from CML ON to CED
transmission (except for
facsimile-to-telephone switching)
0 : 0.5 sec. 1: 2 sec.
5
6
No. of training retries
No. 5 6
0 0 : 1 time
0 1 : 2 times
1 0 : 3 times
1 1 : 4 times
7 Encoding system (Compression): MR 0: Allowed 1: Not allowed
8
Encoding system (Compression):
MMR
0: Allowed 1: Not allowed
Selector 2: Time length from transmission of the last dial digit to CML ON
This selector sets the time length from when the machine transmits the last dial digit until
the CML relay comes on.
Selector 3: Time length from CML ON to CNG transmission
This selector sets the time length until the machine transmits a CNG after it turns on the
CML relay.
Selector 4: Time length from CML ON to CED transmission
This selector sets the time length until the machine transmits a CED after it turns on the
CML relay. This setting does not apply to switching between facsimile and telephone.
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
Selectors 7 and 8: Encoding system (Compression)
This selector determines whether or not to allow the use of the MR/MMR coding system.