Worker Switch Settings (WSW)
SM 5-65 M085/M086
Service
Maintenance
5.3.8 WSW07
Selector No. Function Setting and Specifications
1
2
Dial tone frequency band control
No. 1 2
0 0 : Narrows by 10 Hz
0 1 : Initial value
1 0 : Widens by 10 Hz
1 1 : Widens by 10 Hz
3 Not used.
4 to 6
2nd dial tone detection level
(Z = 600
)
No. 4 5 6
0 0 0 : -21 dBm
0 0 1 : -24 dBm
0 1 0 : -27 dBm
0 1 1 : -30 dBm
1 0 0 : -33 dBm
1 0 1 : -36 dBm
1 1 0 : -39 dBm
1 1 1 : -42 dBm
7
Allowable instantaneous interrupt
during reception of 1st dial tone
0: 30 ms 1: 50 ms
8 Not used.