Worker Switch Settings (WSW)
M085/M086 5-84 SM
5.3.24 WSW23
Selector No. Function Setting and Specifications
1 Starting point of training check (TCF)
0: 0 From the head of a series of
zeros
1: From any arbitrary point
2
3
Allowable training error rate
No. 2 3
0 0 : 0 %
0 1 : 0.5 %
1 0 : 1 %
1 1 : 2 %
4
5
Decoding error rate for transmission of
RTN
No. 4 5
0 0 : 16 %
0 1 : 14%
1 0 : 10 %
1 1 : 8 %
6
7
Not used.
8 Limitation of attenuation level 0: Yes 1: No
Selector 8 is not applicable to the French models.
Selector 1: Starting point of training check (TCF)
At the training phase of receiving operation, the called station detects for 1.0 second a
training check (TCF) command, a series of zeros which is sent from the calling station for
1.5 seconds to verify training and give the first indication of the acceptability of the line.
This selector sets the starting point from which the called station should start counting
those zeros. If this selector is set to "0," the called station starts counting zeros 100 ms after
the head of a series of zeros is detected.
If it is set to "1," the called station starts counting zeros upon detection of 10-ms successive
zeros 50 ms after the head of a series of zeros is detected. In this case, if the detection of
10-ms successive zeros is too late, the data counting period will become less than 1.0
second, making the called station judge the line condition unacceptable.