10. Unscrew the bottle cap [A] and insert the bottle into the holder [B].
NOTE:
Do not open the inner bottle cap [C].
11. Reposition the holder and press down the holder lever [D] to secure the
bottle.
12. Install the optional platen cover if required:
1) Install two stud screws on the top cover.
2) Position the platen cover bracket on the stud screws and slide it to the
left.
13. Pull the paper tray [E] out and turn the paper size dial [F] to select the
appropriate size. Adjust the side guides [G] and end guide [H] to match
the paper size.
14. Turn the ac and main switches on. The machine automatically performs
TD sensor initial setting. Then, check the copy quality and copying
functions.
NOTE:
Do not turn the ac and main switches off or open any covers
during the TD sensor initial setting.
[C]
[A]
[D]
[B]
A193I504.wmf
[H]
[F]
[G]
[E]
A193I505.wmf
1 August 1996 COPIER INSTALLATION
3-7