2.9 ANTI-CONDENSATION HEATER INSTALLATION
CAUTION
Unplug the copier power cord before starting the following procedure.
1. Remove the rear cover and lens cover. (See Rear Cover Removal and
Lens Cover Removal in Section 6.)
2. Hook both ends of the heater [A] onto the clips [B].
3. Push the heater into the two clips.
4. Slide the heater to the left until it clicks into place. Fit the harness [C] into
the clip [D].
NOTE:
Leave the clip out to prevent the heater from slipping off.
5. Insert the connector [E] into the hole.
6. Secure the inner cover [F].
7. Couple the connector coming down from the hole with another connector
[G] coming up from the printer.
NOTE:
Tell the customer that even when the copier’s main switch is
turned off, the copier power cord should be plugged in.
Otherwise, the heater will not function.
[E]
[F]
[G]
A193I510.wmf
[A]
[B]
[C]
[D]
A193I511.wmf
1 August 1996 COPIER INSTALLATION
3-21
Comments to this Manuals