Ricoh SP 200 Specifications Page 173

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 172
4. Remove the 2 clamps [A] and the drum protection sheet [B] from the new PCU.
NOTE:
Do not touch the photoconductor. If you do, copy quality may be
abnormal.
5. Insert the new PCU into the machine. Push the new PCU until the release
lever locks.
6. Peel the sealing tape [C] off gently.
7. Return the lever to its original position (see lever [A] on the previous
page).
NOTE:
After replacing the PCU, the machine will take about 2 minutes to
warm up. During this warm-up period, do not open the front cover
or turn off the ac and main switches or a fault may occur.
[B]
A193R509.wmf
A193R508.wmf
[A]
[C]
A193I502.wmf
1 August 1996 PHOTOCONDUCTOR UNIT (PCU)
6-5
Page view 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 237 238

Comments to this Manuals

No comments