4.3 ORIGINAL SIZE SENSOR
1. Remove the exposure glass. (See Exposure Glass/Operation
Panel/Upper Cover.)
2. Remove the lens covers. (See Lens Cover.)
3. Change the original size sensors [A]: two for 115 V machines and three
for 230 V machines (2 screws each).
4.4 LENS BLOCK/SBU ASSEMBLY
1. Remove the exposure glass and operation panel. (See Exposure
Glass/Operation Panel/Upper Cover.)
2. Remove the lens covers. (See Lens Cover.)
3. Disconnect the flexible harness [B].
4. Remove the grounding wire [C].
5. Remove the lens block [D] (4 screws).
6. Do the scanner and printer copy adjustments in section 11.