Ricoh SP 200 Specifications Page 128

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 127
Mode No.
Function Settings
Class
1 and 2
Class 3
1-902
Fusing
Control
Frequency
Display
Displays the fusing control frequency
which is detected by the zero cross signal
generator.
Around "50" equals 50 Hz. Around "60"
equals 60 Hz.
2-001 *
Charge Roller
Bias
Adjustment
Adjusts the voltage applied to the charge
roller.
-1000 ~ -2500
1 V/step
- 1750 V
Do not change the value.
2-101 *
1
Leading Edge
Erase Margin
(Printing)
Adjusts the leading edge erase margin. 0 ~ 9
1 mm/step
3.0 mm
The specification is 3
±
2 mm. See
"Replacement and Adjustment - Copy
Image Adjustments" for details.
2
Trailing Edge
Erase Margin
(Printing)
Adjusts the trailing edge erase margin. 0 ~ 9
1 mm/step
2.0 mm
The specification is 2
±
2 mm. See
"Replacement and Adjustment - Copy
Image Adjustments" for details.
3
Left Side
Edge Erase
Margin
(Printing)
Adjusts the left side erase margin. 0 ~ 9
1 mm/step
2.0 mm
The specification is 2
±
1.5 mm
.
See
"Replacement and Adjustment - Copy
Image Adjustments" for details.
4
Right Side
Edge Erase
Margin
(Printing)
Adjusts the right side erase margin. 0 ~ 9
1 mm/step
2.0 mm
The specification is 2
±
1.5 mm
.
See
"Replacement and Adjustment - Copy
Image Adjustments" for details.
2-103 *
LD Power
Adjustment
Adjusts the LD power. -128 ~ +127
1
µ
W/step
- 103
Do not change the value.
2-106*
ID Adjustment
for a Test
Pattern
Adjusts the image density level for black
pixels on test pattern printouts (made with
SP5-902).
0 ~ 255
1/step
255
2-201 *
Development
Bias
Adjustment
Adjusts the development bias during
copying.
-200 ~ -900
1 V/step
- 600 V
This can be adjusted as a temporary
measure if faint copies appear due to an
aging drum.
2-213*
Number of
Copies After
Toner Near
End Detection
Selects the number of copies after toner
near-end has been detected.
0: 50 copies
1: 20 copies
2-220 *
V
T
Display Displays the TD sensor output voltage.
Press the key to exit the display.
SERVICE PROGRAM MODE 1 August 1996
4-8
Page view 127