Ricoh SP 1200S Service Manual Page 244

  • Download
  • Add to my manuals
  • Print
  • Page
    / 420
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 243
Worker Switch Settings (WSW)
M085/M086 5-54 SM
5.3.2 WSW01
Selector No. Function Setting and Specifications
1
2
Dial pulse generation mode
No.1 2
0 0 : N
0 1 : N+1
1 0 : 10-N
1 1 : N
3
4
Break time length in pulse dialing
No.3 4
0 0 : 60 ms
0 1 : 67 ms
1 0 : 40 ms
1 1 : 64 ms (for 16 PPS)
5
6
Inter-digit pause
No.5 6
0 0 : 800 ms
0 1 : 850 ms
1 0 : 950 ms (for 16 PPS)
1 1 : 600 ms (at 106-ms
intervals)
7
Switching between pulse and tone
dialing, by the function switch
0: Yes 1: No
8
Default dialing mode, pulse (DP) or
tone (PB) dialing
0: PB 1: DP
Selectors 1 and 2: Dial pulse generation mode
These selectors set the number of pulses to be generated in pulse dialing.
N: Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)
N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.
Selectors 3 and 4: Break time length in pulse dialing