Worker Switch Settings (WSW)
SM 5-67 M085/M086
Service
Maintenance
5.3.9 WSW08
Selector No. Function Setting and Specifications
1 to 3 1st dial tone detection time length
No. 1 2 3
0 0 0 : 50 ms
0 0 1 : 250 ms
0 1 0 : 500 ms
0 1 1 : 620 ms
1 0 0 : 800 ms
1 0 1 : 1.5 sec.
1 1 0 : 2.0 sec.
1 1 1 : 2.5 sec.
4
5
Time-out length for 1st and 2nd dial
tone detection
No. 4 5
0 0 : 10 sec.
0 1 : 20 sec.
1 0 : 15 sec.
1 1 : 30 sec.
6 to 8
Detection level of 1st dial tone and
busy tone before dialing
No. 6 7 8
0 0 0 : -21 dBm
0 0 1 : -24 dBm
0 1 0 : -27 dBm
0 1 1 : -30 dBm
1 0 0 : -33 dBm
1 0 1 : -36 dBm
1 1 0 : -39 dBm
1 1 1 : -42 dBm
The WSW08 is not applicable in those countries where no dial tone detection is
supported, e.g., U.S.A.
Selectors 1 through 3: 1st dial tone detection time length
Upon detection of the 1st dial tone for the time length set by these selectors, the machine
starts dialing. This setting is effective only when selectors 1 through 3 on WSW05 are set to
"1,1,1."