Troubleshooting of the Communications Error
M085/M086 6-70 SM
6.8 TROUBLESHOOTING OF THE COMMUNICATIONS
ERROR
If a communications error occurs, the machine
1. Gives an alarm (intermittent bleep) for approximately four seconds.
2. Indicates the appropriate error message on the LCD.
3. Prints the transmission report during fax transmission.
6.8.1 DEFINITION OF ERROR CODES ON THE COMMUNICATIONS
LIST
1. Calling
Code 1 Code 2 Causes
10 08 Wrong number called.
11 01 No dial tone detected before start of dialing.
11 02 Busy tone detected before dialing.
11 03 2nd dial tone not detected.
11 05 No loop current detected. *
11 06 Busy tone detected after dialing or called.
11 07 No response from the remote station in sending.
11 10 Unobtainable tone detected after dialing.
17 07 No response from the calling station in receiving.
* Available in German models only.