Worker Switch Settings (WSW)
M085/M086 5-106 SM
5.3.55 WSW54
Selector No. Function Setting and Specifications
1
2
Not used.
3
More CNG detection cycles in
user-friendly reception
0: No 1: 2 more cycles
4 Not used.
5
6
Caller ID tone alert detection time
length
No. 5 6
0 0 : 50 ms (default)
0 1 : 60 ms
1 0 : 70 ms
1 1 : 80 ms
7
8
Not used.
Selectors 5 through 7 are applicable only to models designed for the UK market.
Selector 3: More CNG detection cycles in user-friendly reception
If CNG detection fails even after adjustment of selectors 4 and 5 on WSW26, try adding 2
more cycles to the permitted number of CNG detection cycles.
Selectors 5 and 6: Caller ID tone alert detection time length
In the event of a false detection of a caller ID tone alert, adjust the detection time length.