Ricoh SP 1200S Service Manual Page 286

  • Download
  • Add to my manuals
  • Print
  • Page
    / 420
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 285
Worker Switch Settings (WSW)
M085/M086 5-96 SM
5.3.37 WSW36
Selector No. Function Setting and Specifications
1 to 3 Not used.
4 Not used.
5 Escape from phase C 0: Yes 1: No
6 to 8
Extension of incoming calling signal
(CI) frequency band specified by
selectors 1 through 4 on WSW14
No. 6 7 8
0 0 0 : 0 (Ignored)
0 0 1 : 4 (448 Hz)
0 1 0 : 8 (244 Hz)
0 1 1 : 12 (162 Hz)
1 0 0 : 16 (122 Hz)
1 0 1 : 20 (97 Hz)
1 1 0 : 24 (81 Hz)
1 1 1 : 28 (69 Hz)
Selector 5: Escape from phase C
This selector determines whether or not the machine will escape from phase C when it
detects an RTC (Return to Control) in non-ECM mode or an RCP (Return to Control Partial
page) in ECM mode.
Selectors 6 through 8: Extension of incoming calling signal (CI) frequency band
specified by selectors 1 through 4 on WSW14
At the start of reception, if the machine detects the frequency of a CI signal specified by
selectors 1 through 4 on WSW14, it starts the ringer sounding. However, the machine
may fail to detect the CI signal normally due to noise superimposed at the time of reception.
To prevent it, use selectors 6 through 8 on WSW36.
If the machine detects higher frequencies than the setting made here, it regards them as
noise and interprets the detecting state as being normal, allowing the ringer to keep
sounding according to the preset number of ringers (until it starts automatic reception of
FAX data in the FAX mode or enters the TAD mode in the TEL mode).