Worker Switch Settings (WSW)
SM 5-107 M085/M086
Service
Maintenance
5.3.56 WSW55
Selector No. Function Setting and Specifications
1 to 8
Interval of time required for the
developing bias voltage correction
(hour)
0: The developing bias voltage
correction is performed on each
print job.
1-72: The developing bias
voltage correction is performed
when a print job occurs at
specified time or later.
73-254: Not allowed to set.
255 (0xFF): The developing bias
voltage correction is not
performed.
The setting example of the selector number is as follows;
No. 1 2 3 4 5 6 7 8
0 0 0 0 0 0 0 0 : The developing bias voltage correction is performed on each print job.
0 0 0 1 1 0 0 0 : The developing bias voltage correction is performed when a print job occurs
after 24 hours (default value) or later.
0 0 0 1 0 0 1 0 : The developing bias voltage correction is performed when a print job occurs
after 72 hours or later.
1 1 1 1 1 1 1 1 : The developing bias voltage correction is not performed.
Selector 1 to 8: Interval of time required for the developing bias voltage correction
To keep the density of four colors evenly, the developing bias voltage correction is
performed when a print job occurs at specified time or later.