Worker Switch Settings (WSW)
M085/M086 5-100 SM
5.3.40 WSW39
Selector No. Function Setting and Specifications
1 to 4
First transmission speed choice for
fallback
No. 1 2 3 4
No. 5 6 7 8
0 0 0 0 : 2,400 bps
0 0 0 1 : 4,800 bps
0 0 1 0 : 7,200 bps
0 0 1 1 : 9,600 bps
0 1 0 0 : 12,000 bps
0 1 0 1 : 14,400 bps
0 1 1 0 : 16,800 bps
0 1 1 1 : 19,200 bps
1 0 0 0 : 21,600 bps
1 0 0 1 : 24,000 bps
1 0 1 0 : 26,400 bps
1 0 1 1 : 28,800 bps
1 1 0 0 : 31,200 bps
1 1 0 1 : 33,600 bps
1 1 1 0 : 33,600 bps
1 1 1 1 : 33,600 bps
5 to 8
Last transmission speed choice for
fallback
WSW39 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in
models supporting V.34 mode. For the transmission speed setting in other modes, refer
to WSW19.
Selectors 1 through 8: First and last choices of transmission speed for fallback
These selectors are used to set the modem speed range. With the first transmission speed
choice specified by selectors 1 through 4, the machine attempts to establish the
transmission link via the modem. If the establishment fails, the machine automatically steps
down to the next highest speed and attempts to establish the transmission link again. The
machine repeats this sequence while stepping down the transmission speed to the last
choice specified by selectors 5 through 8.